CCJWJ - WALKWAY DARK GULL GRAY #C-8606
- MSDS: CCJWJ
- Manufacturer: AKRON PAINT AND VARNISH INC
- Product Name: WALKWAY DARK GULL GRAY #C-8606
- National Stock Number: 8010-00-641-0428
Product Identification
Product ID:WALKWAY DARK GULL GRAY #C-8606
MSDS Date:01/29/1993
FSC:8010
NIIN:00-641-0428
MSDS Number: CCJWJ
Responsible Party
AKRON, OH 44301-1624
US
Emergency Phone: 330-773-8911
Info Phone: 330-773-8911
Cage: 70228
Contractor
Telephone: 216-773-8911
Cage: 70228
Ingredients
CRYSTALLINE SILICA (CHRONIC HEALTH EFFECTS POSSIBLE IF
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: 24.97%
OSHA PEL 0.1 MP/F3
ACGIH TLV: 0.1 MP/F3
VM&P NAPHTHA RULE 66 (VP = 15 @ 100F)
CAS: 64742-89-8
Fraction By Weight: 33.57%
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CAN CAUSE
REDNESS,IRRIT,SWELLING,BLURRED VISION. SKIN:PROLONGED/REPEATED
CONTACT CAN CAUSE MODERATE IRRIT, DEFATTING, DERMATITIS.
BREATHING:EXCESSIVE INHALATION OF VAPORS AND/OR SPRAY MIST CAN C
AUSE RESPIRATORY IRRITATION,
DIZZINESS/WEAKNESS/FATIGUE/NAUSEA/HEADACHE/UNCONSCIOUSNESS.
Explanation of Carcinogenicity:LIMITED EVIDENCE OF CARCINOGENICITY TO
HUMANS IARC CLASS 2A.
Effects of Overexposure:ASPHYXIATION. INGEST: GASTROINTESTINAL
IRRITATION/NAUSEA/VOMITING/DIARRHEA. ASPIRATION OF MATERIAL INTO
LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
First Aid
First Aid:EYES:FLUSH W/LRG AMTS WATER FOR 15 MIN. LIFT LIDS, GET IMMED
MED AID. SKIN:WASH W/SOAP/WATER REMOVE CONTAM CLOTHES WASH BEFORE
REUSE. CONSULT DR. IF IRRIT PERSISTS. INGEST:DON'T INDUCE VOMITING.
CAN C AUSE CHEM PNEUMONITIS/CAN BE FATAL. GIVE 1-2 GLASSES WATER TO
DILUTE. INHAL:GET FRESH AIR. IF TROUBLE BREATHING GIVE OXYGEN. IF
BREATHING STOPS GIVE ARTIF RESP. KEEP WARM/QUIET. GET MED AID.
Fire Fighting
Flash Point Method:TCC
Flash Point:50.0F,10.0C
Lower Limits:0.9
Upper Limits:7.0
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG. USE
WATER FOR COOLING MATERIAL IN VICINITY OF FIRE.
Fire Fighting Procedures:USE SCBA W/FULL FACEPIECE OPERATED IN
PRESSURE-DEMAND OR OTHER POSITIVE PRESSURE MODE. WEAR PROTECTIVE
CLOTHING.
Unusual Fire/Explosion Hazard:VAPORS HEAVIER THAN AIR, TRAVEL ALONG
GROUND TO IGNITION SOURCE SOME DISTANCE FROM HANDLING POINT.
IGNITION SOURCES:PILOT LIGHTS/SMOKING/HEATERS/ELECTRIC*
Accidental Release
Spill Release Procedures:SMALL:ABSORB
W/RAGS/ABSORBENT/VERMICULITE/OTHER; TRANSFER TO HOOD.
LARGE:ELIMINATE IGNIT SOURCES. DIKE AREA-PREVENT SPREADING.
VENTILATE INDOOR AREA. PUMP LIQUID INTO SALVAGE TANK REMAINING
LIQUID TAK EN UP W/SAND/ABSORB/OTHER. SHOVEL **
Handling
Handling and Storage Precautions:DON'T DROP CNTNRS.NO HEAT/SPARKS/OPEN
FLAME.STORE LRG QTY IN BLDG COMPLY W/OSHA 1910.106. NO PRESSURE TO
EMPTY.NO BREATHE SAND DUST. READ MFG PRECAUTN
Other Precautions:*MOTORS/ELEC SWITCH SPARKS/STATIC DISCHARGE.NO
TORCH-CUT EMPTY CNTNRS.VAPORS IN EMPTY CNTNR MAY EXPLODE.APPLIC TO
HOT SURFACES-SPECIAL PRECAUS.DURING EMERG COND OVEREXPOSE TO DECOMP
PRODS-HEALTH HAZAR D.SYMPTS NOT IMMED APPARENT.GET MED AID.
Exposure Controls
Respiratory Protection:IN UNRESTRICTED VENT AREA USE APPROVED
CHEMICAL/MECHANICAL FILTERS TO REMOVE COMBINATION OF
PARTICULATES/VAPOR. IN CONFINED AREAS, APPROVED AIR LINE TYPE
RESPIRATORS/HOODS.
Ventilation:SUFFICIENT VENT TO KEEP
Eye Protection:CHEMICAL SPLASH GOGGLES COMPLY W/OSHA
Other Protective Equipment:NORMAL PROTECTIVE CLOTHING.
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
***REMOVE HEAVY SOLVENT VAPORS FROM LOWER LEVELS/ELIMINATE ALL IGNIT
SOURCES (USE EXPLOSION PROOF EQUIP) REMOVE DECOMP PRODS FORMED WHEN
WELD/FLAME CUT OF SRFCS COAT W/PROD. BAKE FINISHES: VENT VAPORS
EMITED ON HEAT.
Chemical Properties
HCC:F2
Boiling Pt:B.P. Text:0F,-18C
Vapor Density:>AIR
Spec Gravity:1.22809
Evaporation Rate & Reference:6.72 (N-BUTYL ACETATE)
Appearance and Odor:DARK GULL GRAY LIQUID
Percent Volatiles by Volume:56.7
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZERS (E.G. NITRIC ACID).
Stability Condition to Avoid:KEEP AWAY FROM HEAT AND OPEN FLAME.
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE AND DIOXIDE,
VARIOUS HYDROCARBONS, ETC.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE AND
FEDERAL REGULATIONS. **INTO CNTNRS. PREVENT RUN-OFF TO
SEWERS/BODIES OF WATER. NOTIFY PROPER AUTHORITIES AS REQUIRED BY
LOCAL, STATE AND FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.